Blue Gate Shipping and Trade B.V.
Blue Gate petroleum testing laboratory Rotterdam

Laboratory

On-Site Testing. ASTM-Grade Results.

Twelve standard test methods conducted in the on-site Rotterdam laboratory. Certificates of Analysis issued the same day for time-critical loading and release decisions.

Test Methods

Twelve Tests. All Standard Methods.

PropertyValueMethod / Standard
Distillation profileIBP, 10%, 50%, 90%, FBPASTM D86
Flash pointPensky-Martens closed cupASTM D93
Sulphur contentUV fluorescenceASTM D5453
Density at 15°CDigital oscillating U-tubeASTM D4052
Kinematic viscosityGlass capillary viscometerASTM D445
Water contentKarl Fischer titrationASTM D6304
Sediment by extractionGravimetricASTM D473
Cetane index (calculated)Four-variable equationASTM D976
Freeze point (Jet A1)Automatic cold-stageASTM D2386
Copper strip corrosion3 hr at 50°CASTM D130
Water & sediment (centrifuge)Volume percentASTM D2709
CFPPCold filter plugging pointEN 116

Instrumentation

Purpose-Built Equipment.

Gas Chromatograph

Flame ionisation detector GC for hydrocarbon-type analysis, BTEX quantification, and detailed distillation fingerprinting of Jet A1 and diesel grades.

ICP-OES Spectrometer

Inductively coupled plasma optical emission spectrometer for trace metal analysis — vanadium, nickel, sodium, and silicon in fuel oil and crude grades.

Automatic Distillation Unit

Automated ASTM D86 distillation apparatus with precision temperature control. Three-unit redundancy ensures uninterrupted throughput during high-volume sampling periods.

CFPP Analyser

Automated cold filter plugging point analyser for EN590 diesel grade verification. Critical for seasonal CFPP class confirmation before product release.

Turnaround Times

Results When You Need Them.

Standard analysis — including flash point, density, distillation, and sulphur — is completed within 4 – 6 hours of sample acceptance during normal laboratory hours.

Priority turnaround for time-critical loading decisions is available with results within 2 hours of receipt, subject to current laboratory workload. Out-of-hours analysis can be arranged by prior arrangement.

Indicative only. Exact turnaround windows subject to confirmation with operations team.

Chain of Custody

Sample Integrity. Preserved.

  • Samples registered on receipt with unique batch code and custody seal
  • Sample integrity photograph taken at time of acceptance
  • Sub-samples split and archived for 90 days post-analysis
  • Analysis conducted by named analyst; results counter-signed by laboratory supervisor
  • Certificates of Analysis issued with analyst name, date, instrument ID, and method reference
  • Electronic copies transmitted within agreed turnaround window; originals retained on file

Ready to Submit a Sample?

Contact the laboratory team with your product grade, required tests, and sample dispatch method. We will confirm receipt protocols and expected turnaround on the same day.

Submit Sample →